Insulating Material
Glass-Filled Polycarbonate or
polyesther sulphone
Contact MaterialCopper Alloy
Contact Plating0.000010” gold over .000050” nickel
Contact TailNi/Gold 0.000010”
Current Rating

2.5A at 20°C

1A at 70°C

Operating Voltage300 VAC
Test Voltage1000 VAC
Contact Resistance30 m Ohms max @ 100 mA DC
Insulator Resistance1000M Ohms min @ 500 VDC
Temperature Range
-55°C to + 125°C
Insertion Force
<90 < 20 Lbs
Insertion Cycles
400


The DIN 41612 has been widely accepted as a standard for a variety of interconnection applications in the telecommunications and data markets worldwide. The most widely known use of DIN 41612 connectors is in the VME bus system. 96 pin DIN connectors with three rows(a, b, c) of contacts on 0.100"(2.54mm) square grid are available in wire-wrap or solder tail type terminations.

RE96FABG

RE96FSP

Ordering Info

Standard VME Bus Signals J1 Switched Pins
IACK IN - IACK OUT
a 21-22
BG 0 IN - BG 0 OUT
b 4-5
BG1 IN - BG 0 OUT
b 6-7
BG 2 IN - BG 2 OUT 
b 8-9
BG 3 IN BG 3 OUT
 b 10-11

RE96FABG Specifications

RE96FSR

RE96FSD

Specifications : DIN 41612, Class 2

Downloads

RE96FW

RE96FWP

DIN 41612/IEC 60603-2 Type C Connectors

Connectors

RE96MSR-125

RE96MSR-062

79900003

DIN 41612 connectors | click on image to enlarge

Part

Number

No of

Contacts

GenderOrientation
Type

Contact

Length

RE96MSD96Male
Straight
Solder Tail0.157"
RE96MW
96
Male
Straight
Wire-Wrap
0.54"
RE96MSR-06296MaleRight Angle
Solder Tail0.087"
RE96MSR-12596Male
Right Angle
Solder Tail0.174"
RE96FSD
96
Female
Straight
Solder Tail
0.157"
RE96FSP
96
Female
Straight
Press-fit
0.208"
RE96FW96FemaleStraight
Wire-Wrap0.54"
RE96FWP
96
Female
Striaght
Wire-Wrap, Press-fit
0.670"
RE96FABG96Female
Straight
ABG, Press-fit-
RE96FSR
96
Female
Right Angle
Solder Tail
0.087"
7990000396FemaleStraightShroud-


For automatic daisy chaining of VME and VXI backplanes. Eliminates the need for manual jumpering. Pin entry acts like a switch which is activated. Switches open when male connector is inserted. No other moving parts required. Same MTBF as other types. Requires special installation tooling.

RE96MW